<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-03 00-19-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
87.90 MHz 5/5, 44 dBuV R-VYSOC
Pilot RDS Phase Difference
0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
2 kHz 4 kHz 18092 0,3206
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-5,7 dBr -2,12 dBr 0,4 dBr 1,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-VYSOC " 2D09 9 (Varied) 1 0 1 1 0:19, 3.01.2024
RT
"Cesky rozhlas Vysocina - zijeme tu s vami "
AF EON
87.9, 90.1, 96.5 MHz -
FM Scope Max at: 4 kHz MIN: 2 kHz % above 77 kHz: 0,3206 Acquired: 2024/01/03 0:19:18 Total samples: 18092 Equivalent time: 0:15:04 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 0,4 dBr MIN: -5,7 dBr AVE: -2,12 dBr % above 0,2 dBr: 1,0 Last value: -2,8 dBr (2024/01/03 0:19:17) 00:06 00:08 00:10 00:12 00:14 00:16 00:18 -5 0 Pm [dBr] 0 5 Signal Quality